Ignition Platform - 7.7.1.2014091012-rc3 ========================================================================================== Designer Fixed - Power table was unable to edit int columns as boolean using checkbox editor. Fixed - Query Browser now allows editing of primary keys. Fixed - Fixed up layout issues for classic chart customizer Added Functionality - Equipment Schedule View timeline now scales out to longer time ranges more gracefully Fixed - Tooltips for add and delete button in Tag Editor now display correctly. Fixed - Fixed template repeater opacity issues w.r.t. scrolling Fixed - Fixed the locking of newly created resources Fixed - Fixed ArrayIndexOutOfBoundsException when Linear Scale is missing the Label column. Fixed - All input fields now support translucent backgrounds. Fixed - Prevented IndexOutOfBoundsException caused by bar chart with 1st column not named "Label" Fixed - Fixed NPE trying to apply changes to template instance component event scripts. Fixed - User no longer prompted to save on exit if they don't have permission to save. Fixed - Fixed error caused by setting a Slider component's major tick spacing to zero or less Added Functionality - Added mnemonics to a number of Designer dialog buttons. Fixed - Centered tag export save window relative to parent frame of tag browser. Fixed - Datasource tag history provider not shown in tag history configuration when demo expired. Fixed - Alarm Status Tables show neither Ack'ed By nor Ack Pipeline by default. Fixed - Templates can now be dragged onto windows again when their master editor is open Fixed - Fixed date format property on Alarm Status Tables. Fixed - Save/Exit dialog now treats closing the dialog like choosing cancel. Fixed - Fixed imported global resources not being saved. SQLTags Fixed - Writes to opc tags through system.tag.writeAll(...) are executed individually, which is inefficient. Fixed - Tag history queries in 7.7 resulting in incorrect "stale" data in some circumstances. Fixed - Upgrade to 7.7 creates new historical tag paths, but does not retire previous paths, which can create additional strain on the database. Fixed - Exporting UDT definition as CSV causes an error. Fixed - Max Row Limit error received when executing a tag history query where start time is equal to end time. Added Functionality - Tag UDTs now have access to virtual data type parameters for "InstnaceName" and "TagName". Fixed - Data density histogram not populated on easy chart. Added Functionality - Added user confirmation dialog when adding tags. Gateway Added Functionality - Changed passwords stored in the internal database to not be plaintext Fixed - Active Directory SSO (Single Sign-On) now works across a project retarget. Fixed - Restoring gateway backups no longer require a manual restart of the gateway. Modified Functionality - Removed JDBC/ODBC driver from default JDBC driver list Fixed - OPC server lookups are now case insensitive. Module SDK Fixed - Updated SDK to work with 7.7 Gateway Web Interface Fixed - Submitting a blank license key now gives a more helpful warning. Client Modified Functionality - The Reconnecting panel has been modified for the Designer and clients to give a bit more feedback during reconnection events. Fixed - Translations on templates not always updated when locale changes. Fixed - Modified Designer startup functionality to eliminate the "Component must be showing on the screen to determine its location" error when network connectivity is lost during startup. Scripting Fixed - hasRole() expression on the gateway now complains if the specified user doesn't exist Fixed - Module functions are now available from the tag event scripts Added Functionality - Integrated scripting functions from the IALabs scripting module. Fixed - Unhandled error when editing alarm states through system.tag.editTag Fixed - Added a more informative error when using system.tag.addTag() to add an instance of a non-existent UDT. SQLBridge - 6.7.1.2014091012-rc3 ========================================================================================== Designer Fixed - Transaction group items of String data type show up as integers after upgrade. Fixed - The tag editor no longer allows you to edit the Name property of multiple tags at once (was causing naming collisions). Fixed - UDT instances can affect their parent types and replace parameter references in alarms. Gateway Fixed - Block group doesn't properly store row id when set to "update" mode. Fixed - Hour meters do not work correctly when then item data type is INT, and the time units are not milliseconds. Fixed - Alarm editing not available on block group item when first created. Fixed - Group status monitoring in the designer breaks after restarting the sqlbridge module. Fixed - Error in transaction group when no items target the database. Fixed - Error importing system library in custom python modules executed through tag event scripts. Misc Fixed - Group set to "bi-directional" mode yet set to insert new rows only inserts nulls. Now falls back to "opc-to-db" behavior. Fixed - Tag reference items in groups can now specify a unique name, so that multiple references to the same tag can be made inside of a single group. Code Review Fixed - Custom where clause in transaction groups not being applied correctly. May result in execution errors on some database systems. Vision - 7.7.1.2014091012-rc3 ========================================================================================== Components Added Functionality - Added "onTagsDropped" extension function to the easy chart for custom handling of tag dropping Added Functionality - Equipment Schedule View timeline now shows the day of the month next to the weekday Added Functionality - Equipment Schedule View events can now overlap gracefully in time and will share the vertical space available. Added Functionality - Equipment Schedule View component now allows for event rescheduling by dragging the event's edges. Fixed - Tree component will now sort implicitly created folders in the order their children were first encountered when auto-sort is false Fixed - Fixed power table's incorrect selected row if the table was filtered Fixed - Power Table now correctly adjusts selection when data is deleted. Added Functionality - Power Table popup trigger no longer alters selection. Fixed - Incorrect path created by default when using a tag from a non-default tag provider on an easy chart. Fixed - Fixed incorrect out-of-bounds message when opening a window with a Numeric Text Field. Fixed - Radar plot now supports separate scale for each spoke, desired shape is expected to be the middle regular polygon. Also supports configuration via tag-drop. Added Functionality - The pen datasets are no longer sorted on editing of pens in the easy chart customizer. Added Functionality - The Easy chart now accepts drops from the power table via an extension function. The name of the extension function is "onPowerTableRowsDropped". Added Functionality - Tag Browse Tree will now not show folders that are empty due to the filter settings configured on the component. For example, if only historical tags are shown, folders with no historical tags will not be displayed. Designer Added Functionality - Power Table now allows drag and drop of history tags. Fixed - Fixed bug that could cause deleting a tag via the tree's popup menu to actually delete the selected component. Fixed - Added delete button for private cloud templates Fixed - Dataset Viewer can now edit primitive types. Fixed - Cloud template system wasn't working unless the Designer was run in a Java 8 JRE. Added Functionality - Added notes to templates. Client Added Functionality - Cloud Templates browser will automatically start using new Global Login system when it comes online. Modified Functionality - Client log in screen fields now better proportioned when screen is large. Fixed - If Tag Browse Tree has "show realtime tags" turned off, UDTs with historical and non-historical tags will not be shown. OPC-UA - 2.7.1.2014091012-rc3 ========================================================================================== Misc Fixed - Added scripting hints for system.device.* User Manual - 7.7.1-rc3 ========================================================================================== User Manual Added Functionality - Tag event scripts now log the first occurrence of an error to the gateway console in order to improve error visibility. Misc Fixed - Added descriptions for system.util.getAvailableLocales() and system.util.setLocale() to the User Manual. SFC - null ========================================================================================== Designer Fixed - Charts with a 1x1 note cannot be opened. Client Fixed - Monitoring the status of enclosed charts. WebBrowser - null ========================================================================================== Misc Modified Functionality - Updated underlying libraries. Alarm Notification - 2.7.1.2014091012-rc3 ========================================================================================== Alarm Voice Fixed - Error viewing status page when Voice notification module is installed, but alarm notification module isn't. Alarm Misc Fixed - Alarm events in pipelines become abandoned after tag edits. Allen-Bradley Drivers - 2.7.1.2014091012-rc3 ========================================================================================== MicroLogix/PLC5/SLC Drivers Fixed - Fixed issue for SLC, Micrologix and PLC-5 when only .ACC, .PRE, etc. is subscribed to with out including a sub element 0 item (like .EN), the values are incorrect. Mobile - 2.7.1.2014091012-rc3 ========================================================================================== Backend Added Functionality - Added geolocation (GPS) ability to the mobile module. Added Functionality - Added [System]Mobile/UserAgent and [System]Mobile/RemoteAddr tags for detecting information about the mobile device. OEEDT-Installer-Module-1.7.1.3678-rc3 ========================================================================================== PLEASE NOTE: YOU MUST BACKUP YOUR GATEWAY BEFORE APPLYING THIS UPDATE. THIS RELEASE MOVES THE PRODUCTION MODEL FROM INDIVIDUAL PROJECTS TO THE GLOBAL PROJECT. YOU MAY FIND REFERENCES TO OPC TAGS HAVE CHANGED AND WILL NEED TO BE MODIFIED. IF YOU EXPERIENCE ANY UPGRADE ISSUES PLEASE CONTACT INDUCTIVE AUTOMATION SUPPORT. General Fixed - gateway becomes un-responsive after a save/publish of production model Downtime Improved - Remote operator reason code will allow selection of any reason regardless of the Operator Selectable setting Recipe Fixed - Recipe editor table allows bad values to be entered in manually. Fixed - Recipe editor table resets entered manual value while editing if live value timer update executes. Added - Recipe value name filter to PMIRecipeEditorTable. Fixed - Recipe reports variance exists even though variance tracking is disabled. Fixed - Recipes (if applicable) not automatically being selected when a OEE run was started. Schedule Fixed - PMILineScheduleSelector line schedule only displays work orders, maintenance or other schedule items not selectable. Added - Schedule vs Actual binding function (used by Analysis Time Chart) allows realtime view with look back minutes properties. Quality/SPC Fixed - MedianCalculator: calc() median value was not being assigned correctly. Fixed - SQL Tag collectors with the same name in different locations not saving correct. Web Services Fixed - Error generated when right clicking on web service configuration or listener.